Detection principle: UV dual-path absorption method, used for analysis and detection of ozone concentration in ozone disinfection return air ducts, ozone disinfection cabinets, and ozone aging test chambers. With real-time automatic zero correction function (interval time 5-7 seconds), real-time zero correction once, detection once, detection data is more accurate, and zero point data deviation is effectively avoided.
Measurement range: 0-100PPM; 0-500PPM; 0-1000PPM (customizable 0-10PPM; 0-50PPM)
Wall-Mounted Ozone Gas Concentration Analyzers features: Continuous automatic zero correction to ensure the stability of detection concentration.
Detection principle: UV dual-path absorption method, used for real-time detection of ozone concentration in the box or exhaust ozone concentration.
Measurement range: 0-100ppm; 0-1000ppm
Product features: Desktop Ozone Gas Concentration Analyzer, can run continuously and automatically calibrate to zero, with negative pressure air pump sampling, calibrate the zero point once and detect once, avoid zero point deviation, and ensure the stability of the detection concentration.
Detection principle: UV dual-path absorption method, used for real-time detection of ozone generator outlet concentration or tail gas ozone concentration detection.
Measuring range: 0-100ppm; 0-1000ppm
Product features: Wall-Mounted Ozone Gas Concentration Analyzer can run continuously and automatically calibrate to ensure the stability of the detection concentration.
Dissolved Ozone Water Concentration Analyzer Detection principle: UV dual-path absorption method, used for analysis and detection of dissolved ozone water concentration in pure water or semiconductor industry.
Measuring range: 0-50ppm; 0-100ppm; 0-200ppm; 0-300ppm
Detection principle: UV dual-path absorption method, used for analysis and detection of ozone concentration in ozone disinfection return air ducts, ozone disinfection cabinets, and ozone aging test chambers. With real-time automatic zero correction function (interval time 5-7 seconds (0-100ppm)), real-time zero correction once, detection once, detection data is more accurate, and zero point data deviation is effectively avoided.
Measurement range: 0-100PPM; 0-500PPM; 0-1000PPM (customizable 0-10PPM; 0-50PPM)
Rack-Mounted Ozone Gas Concentration Analyzer features: Continuous operation of automatic zero correction to ensure the stability of detection concentration.
Ozone Gas Concentration Detector Detection principle: dual-path ultraviolet absorption method, using imported ultraviolet LED light source, can be used for ozone generator outlet gas production ozone concentration detection or tail gas ozone concentration detection (need to be equipped with a dehumidification device), can be operated online in real time 24 hours.
Measuring range: 0-300g/Nm3; 0-200g/Nm3; 0-100g/Nm3; 0-50g/Nm3.